contact us
 
: HOME > Á¦Ç°¼Ò°³ > ÁÖÆļö º¯È¯±â

FEATURES
Multi - P.W.M (Pulse Width Modulation) Type
Digital Control ¹æ½Ä
I.G.B.T High Frequency Switching
High Efficiency & Low Audible Noise
Constant Voltage :¡¾1%
Constant Frequency : ¡¾0.5%
¹ÝµµÃ¼ ¹æ½ÄÀÇ Àü¾Ð°¡º¯À¸·Î ±âÁ¸ Slidac¹æ½ÄÀÇ ºÎÇÏ(Load) Àΰ¡½Ã Àü¾Ð º¯µ¿ÀÇ ¹®Á¦Á¡ÀÌ ¾øÀ½
Output Frequency : 50, 60, 45 ~ 500Hz (Variable)
Output Voltage : 0~300V(Variable)
APPLICATIONS
¼ö/ÃâÀÔ Àü±â, ÀüÀÚÁ¦Ç°ÀÇ °³¹ß, »ý»ê ¹× °Ë»ç
°¢ ±â¾÷ ¹× ¿¬±¸¼ÒÀÇ ÁÖÆļö º¯È¯¿ë
½Å·Ú¼º ½ÃÇè¿ë
Æ®·£½ºÆ÷¸Ó °Ë»ç¿ë
¸ðÅͽÃÇè, °Ë»ç¿ë
Standard AC Power Source ¿ë
Á¤Àü¾Ð, Á¤ÁÖÆÄ°¡ ¿ä±¸µÇ´Â ¸ðµç ½ÃÇè ¼³ºñ
 
3»ó DIMENSIONS
MODEL HS-1K HS-3K HS-5K HS-7K HS-10K HS-15K HS-20K HS-30K HS-50K HS-75K HS-100K
Output capacity 1KVA 3KVA 5KVA 7.5KVA 10KVA 15KVA 20KVA 30KVA 501KVA 75KVA 100KVA
circuit type M.P.W.M (multi-pluse width modulation)
input voltage 100V/110V/115V/120V/200V/220V/230V/240V/380V/440V, 1PHASE or 3PHASE(¡¾10%)
input frequency 50Hz / 60Hz
output voltage 0-300V, 1PHASE or 3PHASE
voltage stability ¡Â¡¾1%
output frequency 50, 60, 45-500Hz (Variable)
frequency stability ¡¾0.5%
T.H.D ¡¾3%
protector electronic circuit / over load / short circuit
frequency meter LED digital display
V.A-meter true RMS digital display
temperature 0~40¡É
humidity 0~90%
transfer time zero break
option output voltage : 0 ~ 700V
option remote control (RS-232C : variable voltage, variable frequency) / remote multi control(RS-485)